Bio contamination of surfaces and medical devices in controlled environment areas at a hospital in Morocco
Creators
- 1. Sidi Mohamed Ben Abdellah University
- 2. Regional Health
- 3. Université Hassan 1er
Description
The hospital environment, especially medical devices and surfaces, represents a secondary reservoir for pathogens . This work aims to evaluate the microbiological quality of surfaces and medical equipment of controlled environment services (burn unit, operating room, and sterilization service) at a hospital in Meknes (center of Morocco). This study was carried out for three months (September-December of 2017). A total of 63 samples were taken by swabbing technique from different surfaces and medical equipment after bio-cleaning. Identification was performed according to conventional bacteriological methods and by microscopic observation for fungi. The study showed that 68% of the surface was contaminated. The operating room recorded a rate of 93% of contamination (p-value <0.01), 83% for sterilization service, and 47% for burn unit. A percentage of 67% of the isolates were identified as Gram-positive bacteria against 32% Gram-negative bacteria (p-value <0.05). Bacterial identification showed Coagulase-negative Staphylococci (45%), Enterobacter cloacae (14%), Micrococcus sp (10%), Klebsiella pneumoniae , peptostreptococcus sp and Pseudomonas fluorescens (7% for each one), Escherichia coli, and Methicillin-resistant Staphylococcus aureus (5% for each one). These results require corrective action represented by rigorous cleaning and disinfection procedures.
Translated Descriptions
Translated Description (Arabic)
تمثل بيئة المستشفى، وخاصة الأجهزة الطبية والأسطح، خزانًا ثانويًا لمسببات الأمراض . يهدف هذا العمل إلى تقييم الجودة الميكروبيولوجية للأسطح والمعدات الطبية لخدمات البيئة الخاضعة للرقابة (وحدة الحروق وغرفة العمليات وخدمة التعقيم) في مستشفى في مكناس (وسط المغرب). أجريت هذه الدراسة لمدة ثلاثة أشهر (سبتمبر- ديسمبر 2017). تم أخذ ما مجموعه 63 عينة عن طريق تقنية المسح من أسطح مختلفة ومعدات طبية بعد التنظيف الحيوي. تم إجراء التحديد وفقًا للطرق البكتريولوجية التقليدية والمراقبة المجهرية للفطريات. وأظهرت الدراسة أن 68 ٪ من السطح ملوث. سجلت غرفة العمليات معدل 93 ٪ من التلوث (قيمة p <0.01)، 83 ٪ لخدمة التعقيم، و 47 ٪ لوحدة الحرق. تم تحديد نسبة 67 ٪ من العزلات على أنها بكتيريا موجبة الجرام ضد 32 ٪ من البكتيريا سالبة الجرام (قيمة p <0.05). أظهر التحديد البكتيري أن المكورات العنقودية سلبية التخثر (45 ٪)، والمخاطية المعوية (14 ٪)، والمكورات الدقيقة sp (10 ٪)، والكلبسيلة الرئوية ، والمكورات العقدية الببتونية sp و Pseudomonas fluorescens (7 ٪ لكل واحد)، والإشريكية القولونية، والمكورات العنقودية الذهبية المقاومة للميثيسيلين (5 ٪ لكل واحد). تتطلب هذه النتائج إجراءات تصحيحية تتمثل في إجراءات تنظيف وتطهير صارمة.Translated Description (French)
L'environnement hospitalier, en particulier les dispositifs médicaux et les surfaces, représente un réservoir secondaire pour les agents pathogènes . Ce travail vise à évaluer la qualité microbiologique des surfaces et des équipements médicaux des services en environnement contrôlé (unité de brûlage, salle d'opération et service de stérilisation) dans un hôpital de Meknès (centre du Maroc). Cette étude a été réalisée pendant trois mois (septembre-décembre 2017). Un total de 63 échantillons ont été prélevés par technique d'écouvillonnage sur différentes surfaces et équipements médicaux après le bio-nettoyage. L'identification a été réalisée selon les méthodes bactériologiques conventionnelles et par observation microscopique des champignons. L'étude a montré que 68 % de la surface était contaminée. La salle d'opération a enregistré un taux de contamination de 93 % (valeur p <0,01), 83 % pour le service de stérilisation et 47 % pour l'unité de brûlage. Un pourcentage de 67 % des isolats ont été identifiés comme des bactéries à Gram positif contre 32 % de bactéries à Gram négatif (valeur p <0,05). L'identification bactérienne a montré des staphylocoques Coagulase-négatifs (45 %), Enterobacter cloacae (14 %), Micrococcus sp (10 %), Klebsiella pneumoniae , peptostreptococcus sp et Pseudomonas fluorescens (7 % pour chacun), Escherichia coli et Staphylococcus aureus résistant à la méthicilline (5 % pour chacun). Ces résultats nécessitent une action corrective représentée par des procédures rigoureuses de nettoyage et de désinfection.Translated Description (Spanish)
El entorno hospitalario, especialmente los dispositivos y superficies médicas, representa un reservorio secundario para los patógenos . Este trabajo tiene como objetivo evaluar la calidad microbiológica de las superficies y equipos médicos de los servicios de ambiente controlado (unidad de quemaduras, sala de operaciones y servicio de esterilización) en un hospital en Meknes (centro de Marruecos). Este estudio se realizó durante tres meses (septiembre-diciembre de 2017). Se tomaron un total de 63 muestras mediante la técnica de hisopado de diferentes superficies y equipos médicos después de la biolimpieza. La identificación se realizó de acuerdo con métodos bacteriológicos convencionales y mediante observación microscópica de hongos. El estudio mostró que el 68% de la superficie estaba contaminada. El quirófano registró una tasa de 93% de contaminación (valor p <0.01), 83% para el servicio de esterilización y 47% para la unidad de quemaduras. Un porcentaje del 67% de los aislados se identificó como bacterias Gram-positivas frente al 32% de bacterias Gram-negativas (valor de p <0,05). La identificación bacteriana mostró estafilococos coagulasa negativos (45%), Enterobacter cloacae (14%), Micrococcus sp (10%), Klebsiella pneumoniae , peptostreptococcus sp y Pseudomonas fluorescens (7% para cada uno), Escherichia coli y Staphylococcus aureus resistente a la meticilina (5% para cada uno). Estos resultados requieren una acción correctiva representada por procedimientos rigurosos de limpieza y desinfección.Files
e3sconf_vigisan_01080.pdf.pdf
Files
(24 Bytes)
Name | Size | Download all |
---|---|---|
md5:7624dcbc096921e31a1da610e19a546e
|
24 Bytes | Preview Download |
Additional details
Additional titles
- Translated title (Arabic)
- التلوث البيولوجي للأسطح والأجهزة الطبية في مناطق البيئة الخاضعة للرقابة في مستشفى في المغرب
- Translated title (French)
- Contamination biologique de surfaces et de dispositifs médicaux dans des zones à environnement contrôlé dans un hôpital au Maroc
- Translated title (Spanish)
- Biocontaminación de superficies y dispositivos médicos en áreas de ambiente controlado en un hospital en Marruecos
Identifiers
- Other
- https://openalex.org/W3213434209
- DOI
- 10.1051/e3sconf/202131901080
References
- https://openalex.org/W1552231390
- https://openalex.org/W1902913528
- https://openalex.org/W1966399267
- https://openalex.org/W1970505568
- https://openalex.org/W1976497845
- https://openalex.org/W1984755111
- https://openalex.org/W1985438890
- https://openalex.org/W2004282096
- https://openalex.org/W2009973159
- https://openalex.org/W2025627257
- https://openalex.org/W2047315656
- https://openalex.org/W2059582884
- https://openalex.org/W2064303236
- https://openalex.org/W2067270241
- https://openalex.org/W2069428255
- https://openalex.org/W2088177572
- https://openalex.org/W2090337078
- https://openalex.org/W2094448747
- https://openalex.org/W2105373238
- https://openalex.org/W2106767399
- https://openalex.org/W2113599318
- https://openalex.org/W2126252017
- https://openalex.org/W2132202531
- https://openalex.org/W2145069900
- https://openalex.org/W2149415134
- https://openalex.org/W2149911007
- https://openalex.org/W2152846901
- https://openalex.org/W2160922324
- https://openalex.org/W2294085167
- https://openalex.org/W2538491174
- https://openalex.org/W2624479351
- https://openalex.org/W2990988499
- https://openalex.org/W4247547003