Treatment of medical solid waste using an Air Flow controlled incinerator
- 1. Vietnam Academy of Science and Technology
- 2. Thai Nguyen University
- 3. Saigon University
- 4. Trường ĐH Nguyễn Tất Thành
Description
Abstract In this study, air flow controlled incinerator (AFCI) was used to treat medical solid waste in Vietnam. The experiment was conducted with solid waste samples that was weighed approximately 2.1–3.3 kg/h and had moisture content of 2.8–11.7%. The results showed that an increase in the airflow rate during the drying process accelerated the combustion time by 10–20%, and the optimal airflow rate was 1.1 m/s. The combustion time varied from 0–45 min. The highest temperatures recorded in the drying chamber, carbonisation chamber and combustion chamber after 25–35 min of operation were varied from 195°C, 775°C and 1275°C, respectively. The temperature of the stack was from 33–68°C after the treatment by the wet scrubber using 20% NaOH solution. The combustion capacity was 77.3–87.5%. The experimental results revealed the AFCI process advantages including low operation cost and suitability for treating hazardous waste on a small scale.
Translated Descriptions
Translated Description (Arabic)
الخلاصة في هذه الدراسة، تم استخدام المحرقة المتحكم في تدفق الهواء (AFCI) لمعالجة النفايات الصلبة الطبية في فيتنام. تم إجراء التجربة باستخدام عينات من النفايات الصلبة التي تم وزنها حوالي 2.1-3.3 كجم/ساعة وكان محتوى الرطوبة فيها 2.8–11.7 ٪. وأظهرت النتائج أن الزيادة في معدل تدفق الهواء أثناء عملية التجفيف أدت إلى تسريع وقت الاحتراق بنسبة 10-20 ٪، وكان معدل تدفق الهواء الأمثل 1.1 م/ث. تراوح وقت الاحتراق من 0–45 دقيقة. اختلفت أعلى درجات الحرارة المسجلة في غرفة التجفيف وغرفة الكربنة وغرفة الاحتراق بعد 25–35 دقيقة من التشغيل من 195 درجة مئوية و 775 درجة مئوية و 1275 درجة مئوية على التوالي. كانت درجة حرارة المكدس من 33-68 درجة مئوية بعد المعالجة بواسطة جهاز الغسيل الرطب باستخدام 20 ٪ من محلول هيدروكسيد الصوديوم. كانت قدرة الاحتراق 77.3–87.5 ٪. كشفت النتائج التجريبية عن مزايا عملية AFCI بما في ذلك انخفاض تكلفة التشغيل وملاءمة معالجة النفايات الخطرة على نطاق صغير.Translated Description (French)
Résumé Dans cette étude, un incinérateur à flux d'air contrôlé (AFCI) a été utilisé pour traiter les déchets solides médicaux au Vietnam. L'expérience a été menée avec des échantillons de déchets solides pesant environ 2,1 à 3,3 kg/h et ayant une teneur en humidité de 2,8 à 11,7 %. Les résultats ont montré qu'une augmentation du débit d'air pendant le processus de séchage accélérait le temps de combustion de 10 à 20% et que le débit d'air optimal était de 1,1 m/s. Le temps de combustion variait de 0 à 45 min. Les températures les plus élevées enregistrées dans la chambre de séchage, la chambre de carbonisation et la chambre de combustion après 25–35 min de fonctionnement variaient de 195°C, 775°C et 1275°C, respectivement. La température de la cheminée était de 33-68°C après le traitement par l'épurateur humide en utilisant une solution de NaOH à 20%. La capacité de combustion était de 77,3-87,5 %. Les résultats expérimentaux ont révélé les avantages du procédé AFCI, notamment son faible coût d'exploitation et son aptitude à traiter des déchets dangereux à petite échelle.Translated Description (Spanish)
Resumen En este estudio, se utilizó un incinerador controlado por flujo de aire (AFCI) para tratar residuos sólidos médicos en Vietnam. El experimento se realizó con muestras de residuos sólidos que pesaban aproximadamente 2.1–3.3 kg/h y tenían un contenido de humedad de 2.8–11.7%. Los resultados mostraron que un aumento en el caudal de aire durante el proceso de secado aceleró el tiempo de combustión en un 10–20%, y el caudal de aire óptimo fue de 1,1 m/s. El tiempo de combustión varió de 0–45 min. Las temperaturas más altas registradas en la cámara de secado, la cámara de carbonización y la cámara de combustión después de 25–35 minutos de funcionamiento variaron de 195 ° C, 775 ° C y 1275 ° C, respectivamente. La temperatura de la pila fue de 33-68 °C después del tratamiento mediante el depurador húmedo usando una solución de NaOH al 20%. La capacidad de combustión fue del 77,3-87,5%. Los resultados experimentales revelaron las ventajas del proceso AFCI, incluido el bajo costo de operación y la idoneidad para tratar residuos peligrosos a pequeña escala.Files
pjct-2020-0005.pdf
Files
(576.6 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:f88969bd7cf1925338603ce7d78d67b6
|
576.6 kB | Preview Download |
Additional details
Additional titles
- Translated title (Arabic)
- معالجة النفايات الصلبة الطبية باستخدام محرقة يتم التحكم فيها بتدفق الهواء
- Translated title (French)
- Traitement des déchets solides médicaux à l'aide d'un incinérateur à flux d'air contrôlé
- Translated title (Spanish)
- Tratamiento de residuos sólidos médicos mediante un incinerador controlado por flujo de aire
Identifiers
- Other
- https://openalex.org/W3012484608
- DOI
- 10.2478/pjct-2020-0005
References
- https://openalex.org/W1995583030
- https://openalex.org/W2004246060
- https://openalex.org/W2007782799
- https://openalex.org/W2023556766
- https://openalex.org/W2045893450
- https://openalex.org/W2082365471
- https://openalex.org/W2087666003
- https://openalex.org/W2106245147
- https://openalex.org/W2162696022
- https://openalex.org/W2292205931
- https://openalex.org/W2559845788
- https://openalex.org/W2792334282
- https://openalex.org/W2809970599
- https://openalex.org/W2888222893
- https://openalex.org/W2940804229
- https://openalex.org/W2942008224
- https://openalex.org/W4302202273