La edad y el uso de máscara oronasal se asocian con menor calidad en la titulación con CPAP autoajustable en domicilio en pacientes sin adaptación
Description
Introduction: automated CPAP (APAP) titration at home is considered acceptable (TitAccept) when its device is used ≥ 4 hours/night and the residual apnea index (AHIr) es ≤ 10 events/hour (AASM). However, all the variables related to quality of this procedure are not fully known. Objective: to assess the quality of the titration with APAP at home. Material and Methods: Retrospective study in CPAP "naïve" patients. The TitAccept criterion selected two groups and multiple logistic regression identified predictors of non-acceptable titration. Results: we included 1325 TitAccept; 941 men (71%), age: 57 ± 12.4 years, BMI: 32.3 ± 8.8 kg/m2, baseline AHI: 34.2 ± 19 ev/h. The titration reached 3.4 ± 3.5 nights, adherence: 379 minutes/night; effective pressure: 8.7 ± 1.7 cmH2O, AHIr; 3.1 ± 2.4 ev/h and leaks 16.1 ± 8.7 liters/min. The predictors were; age ≥ 50 years; OR: 1.62 (95%CI: 1.23-3.46), p: 0.0005 and oronasal mask; OR: 2.49 (95%CI: 1.79-3.46), p: 0.0001. Conclusions: a significant proportion of patients who underwent an unsupervised APAP titration at home did not meet adequate test quality. Age ≥50 years and the use of an oronasal mask are associated with lower quality, according to pre-established criteria.
Translated Descriptions
Translated Description (Arabic)
مقدمة: تعتبر معايرة CPAP (APAP) التلقائية في المنزل مقبولة (TitAccept) عند استخدام جهازها ≥ 4 ساعات/ليلة ومؤشر انقطاع النفس المتبقي (AHIr) هو ≤ 10 أحداث/ساعة (AASM). ومع ذلك، فإن جميع المتغيرات المتعلقة بجودة هذا الإجراء غير معروفة تمامًا. الهدف: تقييم جودة المعايرة باستخدام APAP في المنزل. المواد والطرق: دراسة بأثر رجعي على مرضى CPAP "الساذجين". اختار معيار TitAccept مجموعتين وحدد الانحدار اللوجستي المتعدد مؤشرات المعايرة غير المقبولة. النتائج: قمنا بتضمين 1325 TitAccept ؛ 941 رجلاً (71 ٪)، العمر: 57 ± 12.4 سنة، مؤشر كتلة الجسم: 32.3 ± 8.8 كجم/م 2، خط الأساس AHI: 34.2 ± 19 ev/h. وصلت المعايرة إلى 3.4 ± 3.5 ليلة، الالتصاق: 379 دقيقة/ليلة ؛ الضغط الفعال: 8.7 ± 1.7 سم H2O، AHIr ؛ 3.1 ± 2.4 إلكترون/ساعة وتسرب 16.1 ± 8.7 لتر/دقيقة. كانت المؤشرات هي ؛ العمر ≥ 50 سنة ؛ أو: 1.62 (95 ٪CI: 1.23-3.46)، p: 0.0005 وقناع فموي أنفي ؛ أو: 2.49 (95 ٪CI: 1.79-3.46)، p: 0.0001. الاستنتاجات: لم تستوف نسبة كبيرة من المرضى الذين خضعوا لمعايرة APAP غير الخاضعة للإشراف في المنزل جودة الاختبار الكافية. يرتبط العمر ≥50 عامًا واستخدام قناع الفم والأنف بجودة أقل، وفقًا للمعايير المحددة مسبقًا.Translated Description (English)
Introduction: automated CPAP (APAP) titration at home is considered acceptable (TitAccept) when its device is used ≥ 4 hours/night and the residual apnea index (AHIr) is ≤ 10 events/hour (AASM). However, all the variables related to the quality of this procedure are not fully known. Objective: to assess the quality of the titration with APAP at home. Material and Methods: Retrospective study in "naïve" CPAP patients. The TitAccept criterion selected two groups and multiple logistic regression identified predictors of non-acceptable titration. Results: we included 1325 TitAccept; 941 men (71%), age: 57 ± 12.4 years, BMI: 32.3 ± 8.8 kg/m2, AHI baseline: 34.2 ± 19 ev/h. The titration reached 3.4 ± 3.5 nights, adherence: 379 minutes/night; effective pressure: 8.7 ± 1.7 cmH2O, AHIr; 3.1 ± 2.4 ev/h and leaks 16.1 ± 8.7 liters/min. The predictors were; age ≥ 50 years; OR: 1.62 (95%CI: 1.23-3.46), p: 0.0005 and oronasal mask; OR: 2.49 (95%CI: 1.79-3.46), p: 0.0001. Conclusions: a significant proportion of patients who underwent an unsupervised APAP titration at home did not meet adequate test quality. Age ≥50 years and the use of an oronasal mask are associated with lower quality, according to pre-established criteria.Translated Description (French)
Introduction : automated CPAP (APAP) titration at home is considered acceptable (TitAccept) when its device is used ≥ 4 hours/night and the residual apnea index (AHIr) is ≤ 10 events/hour (AASM). However, all the variables related to quality of this procedure are not fully known. Objective : to assess the quality of the titration with APAP at home. Material and Methods : Retrospective study in CPAP "naïve" patients. The TitAccept decision selected two groups and multiple logistic degression identified predictors of non-acceptable titration. Results : we included 1325 TitAccept ; 941 men (71%), age : 57 ± 12.4 years, IMC : 32.3 ± 8.8 kg/m2, baseline AHI : 34.2 ± 19 ev/h. The titration reached 3.4 ± 3.5 nights, adhérence : 379 minutes/night ; effective pressure : 8.7 ± 1.7 cmH2O, AHIr ; 3.1 ± 2.4 ev/h and leaks 16.1 ± 8.7 liters/min. The predictors were ; age ≥ 50 years ; OR : 1.62 (95%CI : 1.23-3.46), p : 0.0005 and oronasal mask ; OR : 2.49 (95%CI : 1.79-3.46), p : 0.0001. Conclusions : a significant proportion of patients who underwent an unsupervised APAP titration at home did not meet adequate test quality. Age ≥50 years and the use of an oronasal mask are associated with lower quality, according to pre-established Gibralia.Files
112.pdf
Files
(440.0 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:9ff27376e8c5742223ab682cf2f28d0f
|
440.0 kB | Preview Download |
Additional details
Additional titles
- Translated title (Arabic)
- يرتبط العمر واستخدام قناع الفم والأنف بانخفاض جودة معايرة CPAP ذاتية الضبط في المنزل في المرضى الذين لا يعانون من التكيف
- Translated title (English)
- Age and oronasal mask use are associated with lower quality of home self-adjusting CPAP titration in patients without adaptation
- Translated title (French)
- L'âge et le port du masque oronasal sont associés à une qualité inférieure dans le titrage avec CPAP auto-ajustable à domicile chez les patients non adaptés
Identifiers
- Other
- https://openalex.org/W4384469343
- DOI
- 10.55720/respirar.15.2.3